Integrated DC Charger Station

Vehicles Served:Logistics vehicles,taxis,ride -hailing vehicles,private cars.

Highlights :

SPECIFICATION

Rated Power 120KW–320 kW THD ≤5% (above 50% load)
Installation Method Floor-mounted Human-machine Interface 7 -inch screen
Wiring Method Bottom in, bottom out Advertisement Screen Size 500mm*600mm
Input Voltage AC380 V±15% Charging Method Fixed energy/fixed amount/fixed time
Input Frequency 45–65 Hz Payment Method Card -swiping payment/scan -code payment
Output Voltage DC200–1000 V Networking Method Ethernet 3G/4G
Maximum Current per Gun 250 A Efficiency ≥95.2%
Cable Length 5 m Operating Temperature -25℃~+55°C
Metering Accuracy Grade 1 Operating Humidity 5%~95% without condensation
Over-current Protection Value ≥110% Operating Altitude ≤2000 m
Voltage Stability Accuracy ≤0.5% Protection Rating IP55
Current Stability Accuracy ≤±1% Cooling Method Air -cooled
Ripple Factor ≤±0.5% Overall Dimensions 800*750*2000mm
Power Factor ≥0.99 (above 50% load) MTBF 100,000 hours
Compliance Standards GB/T 18487, IEC 61851, IEC 62196, SAE J1772 / /